No image available
· 2018
Abstract: Background Randomized controlled trials have reported favorable 1-year outcomes with drug-coated balloons (DCBs) for the treatment of symptomatic peripheral arterial disease when compared with standard percutaneous transluminal angioplasty (PTA). Evidence remains limited on the durability of the treatment effect with DCBs in the longer term. Methods and Results IN.PACT SFA is a single-blind, randomized trial (Randomized Trial of IN.PACT Admiral Paclitaxel-Coated Percutaneous Transluminal Angioplasty [PTA] Balloon Catheter vs Standard PTA for the Treatment of Atherosclerotic Lesions in the Superficial Femoral Artery [SFA] and/or Proximal Popliteal Artery [PPA]) that enrolled 331 patients with symptomatic (Rutherford 2-4) femoropopliteal lesions up to 18 cm in length. Patients were randomized 2:1 to receive treatment with DCB or PTA. The 36-month assessments included primary patency, freedom from clinically driven target lesion revascularization, major adverse events, and functional outcomes. At 36 months, primary patency remained significantly higher among patients treated with DCB compared with PTA (69.5% versus 45.1%; log rank P0.001). The rates of clinically driven target lesion revascularization were 15.2% and 31.1% (P=0.002) for the DCB and PTA groups, respectively. Functional outcomes were similarly improved between treatment groups even though subjects in the DCB group required significantly fewer reinterventions versus those in the PTA group (P0.001 for target lesion revascularization, P=0.001 for target vessel revascularization). There were no device- or procedure-related deaths as adjudicated by an independent Clinical Events Committee.brbrConclusionsbrThree-year results demonstrate a durable and superior treatment effect among patients treated with DCB versus standard PTA, with significantly higher primary patency and lower clinically driven target lesion revascularization, resulting in similar functional improvements with reduced need for repeat interventions.br
No image available
No image available
No image available
· 2023
Abstract: Background Long-term data on drug-coated balloon (DCB) outcomes in complex femoropopliteal atherosclerotic lesions are limited. Objectives The authors sought to report 5-year safety and effectiveness outcomes of a paclitaxel DCB for the treatment of de novo in-stent restenosis (ISR), long lesions (LL), or chronic total occlusions (CTOs) in the prespecified imaging cohorts of the IN.PACT Global Study. Methods The IN.PACT Global study was a prospective, international single-arm study. Assessments through 5 years included freedom from clinically driven target lesion revascularization (CD-TLR), a safety composite (freedom from device- and procedure-related death to 30 days, and freedom from major target limb amputation and freedom from clinically driven target vessel revascularization within 60 months), and major adverse events. Results The prespecified imaging cohorts enrolled 132 de novo ISR, 158 LL, and 127 CTO participants. Kaplan-Meier estimates of freedom from CD-TLR through 5 years were 58.0% (ISR), 67.3% (LL), and 69.8% (CTO). The cumulative incidences of the composite safety endpoint were 56.0% (ISR), 65.7% (LL), and 69.8% (CTO). The 5-year freedom from all-cause mortality with vital status update were 81.4% (ISR), 75.2% (LL), and 78.2% (CTO). Within the ISR cohort, 15.9% of participants experienced 2 or more TLRs, compared with 9.5% and 5.5% in the LL and CTO groups, respectively. Conclusions Results demonstrate long-term safety and effectiveness of this DCB in all 3 cohorts, with low reintervention rates in the LL and CTO cohorts and no safety issues. These results support the inclusion of this DCB into the treatment algorithm for complex femoropopliteal disease
No image available
· 2021
Abstract: Purpose After promising small randomized trials, the aim of BIOLUX P-III was to further investigate the safety and performance of the Passeo-18 lx drug-coated balloon in infrainguinal arteries under real-world conditions. Methods BIOLUX P-III is a global prospective single-arm study with follow-up at 6, 12 and 24 months. The primary safety endpoint was freedom from major adverse events (MAE) within 6 months. The primary performance endpoint was freedom from clinically driven target lesion revascularization (TLR) within 12 months. Results 877 patients/1084 lesions were enrolled. Diabetes mellitus was present in 47.7%, and 42.1% had critical limb ischemia (CLI). The mean lesion length was 89.0 mm with 76.1% of calcified lesions, and 24.9% occluded. At 24 months, freedom from MAE was 83.1% in the full cohort; 84.9% in the femoropopliteal population (592 patients, 691 lesions); 77.7% for long lesions (187 subjects/192 lesions); and 72.5% in the in-stent restenosis (ISR) subgroup (103 subjects/116 lesions). Twenty-four-month freedom from clinically driven TLR was 88.1% in the full cohort; 88.9% in the femoropopliteal population; 80.3% for the long lesions; and 78.4% for ISR. Twenty-four-month all-cause mortality was 12.0% in the full cohort, 10.2% in the femoropopliteal population, 14.8% for the long lesions and 12.0% for ISR. There was no device- or procedure-related death up to 24-month follow-up. Conclusion The BIOLUX P-III 24-month outcomes confirm the safety and performance of Passeo-18 lx in infrainguinal arteries in a large population treated under real-world conditions with low complication rates and good clinical outcomes (NCT02276313)
No image available
· 2018
Abstract: Background The IN.PACT Global Study was an international prospective single-arm clinical trial to evaluate the safety and effectiveness of a drug-coated balloon in the treatment of atherosclerotic disease of the superficial femoral and/or popliteal arteries (P1-P3) in subjects with intermittent claudication and/or rest pain. Prespecified subjects were selected for core-laboratory-adjudicated duplex ultrasound imaging, including a subcohort with long lesions (≥15 cm). Methods and Results Subjects were followed for 12 months. The primary safety end point was a composite of freedom from device- and procedure-related mortality through 30 days and freedom from major target limb amputation and clinically-driven target vessel revascularization through 12 months. An independent Clinical Events Committee adjudicated all adverse events. The primary effectiveness end point was primary patency at 12 months (by duplex ultrasound). The long lesion imaging cohort had 157 subjects (164 lesions). Mean lesion length was 26.40±8.61 cm. Provisional stents were implanted in 39.4% (63/160) of lesions. Primary patency by Kaplan-Meier estimate was 91.1%, and freedom from clinically-driven target lesion revascularization was 94.2% at 12 months. The primary safety composite end point was achieved by 94.0% (126/134) of subjects. There were no device- or procedure-related deaths or major target limb amputations. Conclusions The IN.PACT Admiral drug-coated balloon was safe and highly effective at 12 months after treatment in a rigorous independently adjudicated analysis of real-world subjects with lesions ≥15 cm in the superficial femoral and/or popliteal arteries (P1-P3)
No image available
· 2022
Abstract: Background: A clear patency benefit of a drug-eluting stent (DES) over bare metal stents (BMSs) for treating peripheral artery disease of the femoropopliteal segment has not been definitively demonstrated. The EMINENT study (Trial Comparing Eluvia Versus Bare Metal Stent in Treatment of Superficial Femoral and/or Proximal Popliteal Artery) was designed to evaluate the patency of the Eluvia DES (Boston Scientific, Marlborough, MA), a polymer-coated paclitaxel-eluting stent, compared with BMSs for the treatment of femoropopliteal artery lesions. Methods: EMINENT is a prospective, randomized, controlled, multicenter European study with blinded participants and outcome assessment. Patients with symptomatic peripheral artery disease (Rutherford category 2, 3, or 4) of the native superficial femoral artery or proximal popliteal artery with stenosis ≥70%, vessel diameter of 4 to 6 mm, and total lesion length of 30 to 210 mm were randomly assigned 2:1 to treatment with DES or BMS. The primary effectiveness outcome was primary patency at 12 months, defined as independent core laboratory-assessed duplex ultrasound peak systolic velocity ratio ≤2.4 in the absence of clinically driven target lesion revascularization or surgical bypass of the target lesion. Primary sustained clinical improvement was a secondary outcome defined as a decrease in Rutherford classification of ≥1 categories compared with baseline without a repeat target lesion revascularization. Health-related quality of life and walking function were assessed. Results: A total of 775 patients were randomly assigned to treatment with DES (n=508) or commercially available BMSs (n=267). Baseline clinical, demographic, and lesion characteristics were similar between the study groups. Mean lesion length was 75.6±50.3 and 72.2±47.0 mm in the DES and BMS groups, respectively. The 12-month incidence of primary patency for DES treatment (83.2% [337 of 405]) was significantly greater than for BMS (74.3% [165 of 222]; P0.01). Incidence of primary sustained clinical improvement was greater among patients treated with the DES than among those who received a BMS (83.0% versus 76.6%; P=0.045). The health-related quality of life dimensions of mobility and pain/discomfort improved for the majority of patients in both groups (for 66.4% and 53.6% of DES-treated and for 64.2% and 58.1% of BMS-treated patients, respectively) but did not differ significantly. At 12 months, no statistical difference was observed in all-cause mortality between patients treated with the DES or BMS (2.7% [13 of 474] versus 1.1% [3 of 263]; relative risk, 2.4 [95% CI, 0.69-8.36]; P=0.15).brConclusions:brbrBy demonstrating superior 1-year primary patency, the results of the EMINENT randomized study support the benefit of using a polymer-based paclitaxel-eluting stent as a first-line stent-based intervention for patients with symptomatic peripheral artery disease attributable to femoropopliteal lesions.brRegistration:br
No image available
· 2022
Abstract: Background Endovascular treatment of calcified peripheral artery lesions may be associated with suboptimal vessel expansion, increased complication risk, and reduced long-term patency. The primary endpoint from the Disrupt PAD III randomized controlled trial (RCT) demonstrated superior procedural success in patients treated with intravascular lithotripsy (IVL) vs percutaneous transluminal angioplasty (PTA). The present study evaluates primary patency after 1 and 2 years in this randomized population. Methods The Disrupt PAD III RCT enrolled 306 patients with moderately-to-severely calcified femoropopliteal arteries treated with IVL (n = 153) or PTA (n = 153) prior to DCB treatment or stenting. The powered secondary effectiveness endpoint was primary patency at 1 year, defined as freedom from clinically driven target lesion revascularization plus freedom from restenosis determined by duplex ultrasound. Acute PTA failure requiring stent placement during the index procedure was prespecified as a loss of primary patency. Results Primary patency at 1 year was significantly greater in the IVL arm (80.5% vs 68.0%, P = .017). The requirement for provisional stenting was significantly lower in the IVL group (4.6% vs 18.3%, P .0001). Freedom from clinically driven target lesion revascularization (IVL: 95.7% vs PTA: 98.3%, P = .94) and restenosis rates (IVL: 90.0% vs PTA: 88.8%, P = .48) were similar between the 2 groups at 1 year. At 2 years, primary patency remained significantly greater in the IVL arm (70.3% vs 51.3%, P = .003).brConclusionsbr
No image available
· 2022
Abstract: Background Drug-coated balloons (DCB) are frequently used to treat femoropopliteal artery disease. However, patency loss occurs in ≥10% of patients within 12 months posttreatment with poor understanding of the underlying mechanisms. Objectives The authors sought to investigate the determinants of DCB failure in femoropopliteal disease. Methods Data from randomized clinical trials (IN.PACT SFA, MDT-2113 SFA Japan) and 2 prespecified imaging cohorts of the IN.PACT Global Clinical Study were included. Influential procedural characteristics were evaluated by an independent angiographic core laboratory. The primary endpoint was DCB failure (patency loss during follow-up). Additional endpoints were binary restenosis and clinically driven target lesion revascularization. Multivariable analyses evaluated the clinical, anatomical, and procedural predictors of DCB failure. Results Included were 557 participants with single lesions and 12-month core laboratory-adjudicated duplex ultrasonography. Key clinical characteristics were as follows: mean age 68.8 years, 67.5% male, 87.6% with hypertension, 76.9% with hyperlipidemia, 40.5% with diabetes mellitus, 90.5% in Rutherford Classification Category (RCC) 2 to 3, and 9.5% in RCC 4 to 5. Average length and reference vessel diameter (RVD) were 16.37 cm and 4.66 mm, respectively; 49.7% of lesions were totally occluded. In multivariable analysis, only residual stenosis >30% was associated with patency loss, whereas residual stenosis >30% and smaller preprocedure RVD were associated with increased binary restenosis risk. RCC >3 and residual stenosis >30% were associated with increased 12-month clinically driven target lesion revascularization risk. Conclusions Patency loss after DCB treatment was influenced by procedural and clinical factors. Residual stenosis >30%, smaller preprocedure RVD, and higher RCC may be considered predictors of increased risk of DCB failure and its components in femoropopliteal artery disease. (Randomized Trial of IN.PACT Admiral® Drug Coated Balloon vs Standard PTA for the Treatment of SFA and Proximal Popliteal Arterial Disease [INPACT SFA I]; NCT01175850; IN.PACT Admiral Drug-Coated Balloon vs. Standard Balloon Angioplasty for the Treatment of Superficial Femoral Artery [SFA] and Proximal Popliteal Artery [PPA] [INPACT SFA II]; NCT01566461; MDT-2113 Drug-Eluting Balloon vs. Standard PTA for the Treatment of Atherosclerotic Lesions in the Superficial Femoral Artery and/or Proximal Popliteal Artery [MDT-2113 SFA]; NCT01947478; IN.PACT Global Clinical Study; NCT01609296)
No image available