    Cellulose paper and mineral oil insulation degrade at higher temperatures. Degradation is accelerated in the presence of oxygen and moisture. Power transformers being expensive items need to be carefully monitored through-out its operation. Well established time-based maintenance and conservative replacement planning is not feasible in a current market driven electricity industry. Condition based maintenance and online monitoring are now gaining importance. This study presents the results of physical-chemical diagnostic tests performed on nine KELAGʼs power transformers (3 transmittion and 5 generation) during normal operation in spring 2005. Diagnosis is made for each transformer in regard to its oil type and quality, thermal and electrical incipient faults as well as paper insulation humidity and degree of aging. Three modern online diagnostic techniques (DGA test, HPLC test, Chem oil tes) were used which are currently in use to asses the insulation condition by EIMV experts and in the world. As the aim of the study was to describe the usability of HPLC test method - furanic compounds in oil analysis - the first part of the study contains information regarding paper aging, degree of polymerization and its correlations to furanics in oil. As today no standard interpretation of HPLC test results in regard to transformer aging degree is available a more detailed discussion is made on criterions for end of transformers life and statistical overview of different transformer populations in regard to 2FAL concentrations in oil. The correlation chart used for the nine tested transformers is presented. The most important factors which affect the aging degree and 2FAL-DP correlation are described and further needed testing or needed information are described.

  • No image available

    This document contains technical specification for variable shunt reactors to serve in the process of bidding. The basis for formulating its content was in references cited standards and other publications. The experiences and practices acquired during ordering of 300 MVA power transformers installed in the last period of time in the Slovenian 400 kV network were implemented too.

  • No image available

    This document contains technical specification for variable shunt reactors to serve in the process of bidding. The basis for formulating its content was in references cited standards and other publications. The experiences and practices acquired during ordering of 300 MVA power transformers installed in the last period of time in the Slovenian 400 kV network were implemented too.

  • No image available

    This document contains technical specification for variable shunt reactors to serve in the process of bidding. The basis for formulating its content was in references cited standards and other publications. The experiences and practices acquired during ordering of 300 MVA power transformers installed in the last period of time in the Slovenian 400 kV network were implemented too.

  • No image available

  • No image available

  • No image available

    Za zagotavljanje čim večje zanesljivosti obratovanja energetskih transformatorjev v TE-TOL se izvajajo različne periodične preventivne diagnostične preiskave, električne meritve in preizkusi energetskih transformatorjev. Rezultati analiz, ocene ter priporočila teh preiskav in preizkusov omogočajo sprotno planirano izvajanje korektivnih ukrepov za zagotavljanje zanesljivega obratovanja in čim daljše tehnične življenjske dobe transformatojev s čim manjšim številom neplaniranih prekinitev obratovanja. V nalogi je izdelana pregledna ocena stanja treh energetskih transformatorjev (TR2, TR7, TR19) na osnovi vseh dosedanjih rezultatov diagnostičnih preiskav in električnih meritev, kjer je mogoče ocenjevanje posameznih parametrov tudi na osnovi opažanja časovnih trendov, medsebojnih korelacij, upoštevanja dogodkov in obremenitev specifičnosti, obnovitev posegov ter podrobnosti materialov in konstrukcij. Izdelan je pregled starostne strukture in ocena preostale življenjske dobe na osnovi izračunov časa v katerem bo dosežen kritičen parameter za sposobnost varnega obratovanja. Izsledki naloge nudijo podlago za ocenjevanje zanesljivosti delovanja transformatorjev v naslednjih letih. Omogočajo strokovno sprejemanje odločitev o planiranju diagnostike, vzdrževanja, revitalizacij in zamenjave ostarelih transformatorjev.

  • No image available

    V študiji so raziskani različni vidiki, ki utemeljujejo potrebo po vključitvi dodatnega - drugega transformatorja 400/110 kV v RTP Okroglo. Tako energetske razmere, kot vpliv na kakovost napetosti v omrežju in ocena stanja in zanesljivost obratovanja obstoječega 400/110 kV transformatorja T411. V prvem delu študije je podan bodoči razvoj tranformacije v RTP Okroglo, ki temelji na dolgoročnem razvojnem planu celotnega EES-a Slovenije do leta 2025, vključno z razvojem distribucijskega napajalnega 110 kV omrežja in načrtovanimi interkonekcijskimi vodi. Podrobneje so analizirana različna obratovalna stanja v prenosnem omrežju na območju med Ljubjano in Gorenjsko, pri čemer so upoštevane možnosti izgradnje nove 110 kV povezave med Kamnikom in Primskovim. Rezultati analiz so pokazali, da bi lahko z ojačitvijo transformacije v RTP Okroglo, dolgoročno in ob boljši kakovosti zagotovili tudi zanesljivejše napajanje celotnega Ljubljansko-Gorenjskega območja. V drugem delu študije so izračunane kratkostične razmere po vključitvi drugega transformatorja v RTP Okroglo. Raziskan je vpliv drugega tranformatorja na kakovost napetosti. Narejene so simulacije za parameter kakovosti napetosti, ki je trenutno najbolj problematičen na tem območju, hitre napetostne sremembe (fliker). Raziskanih je več variant mogočih obratovalnih stanj omrežja in podan je vpliv vključitve drugega transformatorja na parameter fliker v omrežju. V tretjem delu študije je podan celovit prikaz stanja obstoječega transformatorja T 411, izdelan na osnovi fizikalno-kemijske-električne diagnostike Elektroinštituta Milan Vidmar kot tudi dodatnih strokovnih ocen inštituta CEZI, Italija ter prof. dr. Lenassija, FE Ljubljana. Stanje transformatorja je ocenjeno kot zelo slabo, zaradi toplotnih anomalij, lokalne razkrojenosti papirne izolacije navitij, visoke vlažnosti papirne izolacije in kritične razkrojenosti oljne izolacije. Funkcionalno v dielektričnem pogledu je sicer še sposoben za obratovanje vendar je njegova zanesljivost obratovanja zelo zmanjšana zaradi velike nevarnosti mehanskih poškodb papirne izolacije in posledično hitrega dielektričnega zloma, ob minimalnih prenapetostnih, kratkostičnih in mehanskih preobremenitvah ali na hitričh temperaturnih spremembah (vklop, izklop). Zato je za zagotovitev normalne zanesljivosti transformacije 400/110 kV nujno čim prej pridobiti novi nadomestni transformator. Glede na preverjeno stanje ostalih dveh enakovrstnih transformatorjev 400/110 kV v EES, v primeru havarije T 411 v RTP Okroglo, ni možnosti nadomestitve s katerim od obstoječih transformatorjev.